The purpose of the inspection was to make an assessment of the general condition of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. This dam is classified as a small size dam with a high downstream hazard potential. Failure would threaten the life and property of approximately 3 families downstream of the dam and cause appreciable damage to highway FF, approximately 800 feet downstream of the dam. The spillway does not meet the criteria set forth in the guidelines for a dam having the above mentioned size classification and hazard potential. According to the guidelines, the spillway is required to pass the Probable Maximum Flood (PMF) without the dam embankment being overtopped. The spillway will only pass 38 percent of the PMF before the dam embankment is overtopped.

Because the spillway will not pass 1/2 of the PMF without overtopping, the dam is classified as ‘unsafe non-emergency.’ The spillway will pass the 100-year flood without overtopping, which is a flood that has a 1 percent chance of being exceeded in any given year

  • Creator/s: Defense Technical Information Center
  • Date: 8/1/1978
  • Year: 1978
  • Book Topics/Themes: DTIC Archive, , ARMY ENGINEER DISTRICT ST LOUIS MO, *EARTH DAMS, STABILITY, HYDROLOGY, DEFICIENCIES, SAFETY, VISUAL INSPECTION, FLOODING, RESERVOIRS, MISSOURI

An excerpt captured from the PDF book

DTIC ADA1046996: National Dam Safety Program. Maddox_book-excerpt

Report Broken Link

File Copyright Claim

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

Categories

You might be also interested in these Books

Related Posts
PDF Viewer

الرجاء الانتظار بينما يتم تحميل الـ PDF…
HTML Popup Example