NASA Technical Reports Server (NTRS) : High pdf

NASA Technical Reports Server (NTRS) : High_bookcover

NASA Technical Reports Server (NTRS) : High

More Book Details

Description of the Book:

Conventional resistance strain gage technology uses “bonded” strain gages. These foil or wire gages are bonded onto the surface of the test article with glue, ceramic cements, or flame-sprayed ceramics. These bonding agents can, in some instances, limit both the degree of strain transmission from the test structure to the gage and the maximum working temperature of the gage. Also, the bulky, bonded gage normally disrupts aerodynamic gas flow on the surface of the test structure because of its intrusive character. To respond to the urgent needs in aeronautic and aerospace research where stress and temperature gradients are high, aerodynamic effects need to be minimized, and higher operational temperatures are required, the NASA Lewis Research Center developed a thin film strain gage. This gage, a vacuum-deposited thin film formed directly on the surface of a test structure, operates at much higher temperatures than commercially available gages do and with minimal disruption of the aerodynamic flow.

The gage uses an alloy, palladium-13 wt % chromium (hereafter, PdCr), which was developed by United Technologies Research Center under a NASA contract. PdCr is structurally stable and oxidation resistant up to at least 1100 C (2000 F); its temperature-induced resistance change is linear, repeatable, and not sensitive to the rates of heating and cooling. An early strain gage, which was made of 25-micrometer-diameter PdCr wire and demonstrated to be useable to 800 C, won an R&D 100 award in 1991. By further improving the purity of the material and by developing gage fabrication techniques that use sputter-deposition, photolithography patterning, and chemical etching, we have made an 8- to 10-m PdCr thin-film strain gage that can measure dynamic and static strain to at least 1100 C. For static strain measurements, a 5-m-thick Pt element serves as a temperature compensator to further minimize the temperature effect of the gage. These thin-film gages provide the advantage of minimally intrusive surface strain measurements and give highly repeatable readings with low drift at temperatures from ambient to 1100 C.

This is a 300 C advance in operating temperature over the PdCr wire gage and a 500 C advance over commercially available gages made of other materials

  • Creator/s: NASA Technical Reports Server (NTRS
  • Date: 1/1/2005
  • Year: 2005
  • Book Topics/Themes: NASA Technical Reports Server (NTRS), HIGH TEMPERATURE, STRAIN GAGES, THIN FILMS, CHROMIUM, PALLADIUM, MECHANICAL PROPERTIES, ETCHING, STRAIN MEASUREMENT, TEMPERATURE GRADIENTS, PHOTOLITHOGRAPHY, GAS FLOW, SENSITIVITY, SPUTTERING, VACUUM DEPOSITION

An excerpt captured from the PDF book

NASA Technical Reports Server (NTRS) : High_book-excerpt

Report Broken Link

File Copyright Claim

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

Categories

You might be also interested in these Books

Related Posts
PDF Viewer

الرجاء الانتظار بينما يتم تحميل الـ PDF…
HTML Popup Example