Nucleate pool boiling performance of finned and pdf

Nucleate pool boiling performance of finned and_bookcover
  • book-title-icon-openmaktaba Book Title: Nucleate pool boiling performance of finned and
  • used-language-icon-openmaktaba Language: English
  • book-post-date-icon-openmaktaba Post Date: 2025-04-06 18:13:49
  • book-size-in-mbs-openmaktaba PDF Size: 4.41 MB
  • number-of-pages-icon-openmaktaba Book Pages: 105
  • publisher-icon Publisher: Monterey, California. Naval Postgraduate School
  • readonline icon Read Online: Read PDF Book Online
  • PDF Download: Click to Download the PDF
  • Tags:

Nucleate pool boiling performance of finned and

More Book Details

Description of the Book:

The heat transfer characteristics of pure R-114 and R-114/oil mixtures during nucleate pool boiling from a small bundle of finned and High Flux tubes were measured. The bundles had 5 instrumented and 10 additional heated tubes of 15.8 mm outside diameter which were arranged in an equilateral triangular pitch of 19.1 mm giving a pitch-to-diameter ratio of 1.2. Pure refrigerant with York-C lubrication oil mass con-centrations of 1, 2, 3, 6 and 10% was used. All experiments were performed at 2.2C corresponding to a pressure slightly below atmospheric. Data sets were taken using decreasing heat flux only in order to avoid the boiling hysterisis phenomenon. An enhancement in heat-transfer performance of the finned tube bundle due to oil applications was observed. The enhancement increased with up to 3% oil concentration over all heat flux ranges. Further oil additions showed better performances than pure R-114 at high heat flux levels but poorer performance was obtained at lower heat fluxes.

High flux tube experiments indicated that the heat transfer performance of the bundle was approximately 2.5 times better than the finned tube bundle performance for pure R-114. No positive performance enhancement was observed from the High Flux tube bundle due to oil addition. The performance immediately degraded with 1% oil and stayed almost constant with 2% and 3% oil additions. A decrease of performance became significant at high heat flux levels with oil concentrations of 6% and 10%. The performance of these two tube bundles was compared to smooth tube operation

  • Creator/s: Akcasayar, Nezih
  • Date: 12/1/1989 0:00
  • Book Topics/Themes: Heat Transfer, Pool boiling

An excerpt captured from the PDF book

Nucleate pool boiling performance of finned and_book-excerpt

Report Broken Link

File Copyright Claim

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

Categories

You might be also interested in these Books

Related Posts
PDF Viewer

الرجاء الانتظار بينما يتم تحميل الـ PDF…
HTML Popup Example